85 ON 1 bar < P < 13 bar 1 bar < P < 13 bar OFF 1 2 3 12 1 bar < P < 13 bar 1 bar < P < 13 bar ON 1 2 3 12 TRANSAIR ® Ø 40 SHUT-OFF VALVE APPLICATION OPERATING PRINCIPLE Assembled by simple and fast connection to aluminium pipe, the Transair ® Ø40 remote shut-off valve allows network supply to be rapidly and safely opened and closed either at ground level or by remote control. The Transair ® remote shut-off valve thus guarantees : • Personal safety, by eliminating all hazards related to working at heights. • Servicing speed, by removing the need for special access equipment (ladder, platform etc) Remote shut-off valve Pneumatic ON - OFF Polyurethane twin tubing Single acting valve - normally closed. For compressed air networks: the valve control pressure can be taken upstream of the isolating valve, with no external power supply. Control is performed through the control unit connected to the valve by means of a push-in connector. For vacuum networks: a compressed air supply external to the control unit is required, and the corresponding valve port must be closed in order to prevent loss. Installation Guide