13 1/2 -8 M8x1.25 24 5/16-18 24 19 3/4 -12 M10x1.5 50 3/8-16 43 25 1 -16 M10x1.5 50 3/8-16 43 32 1-1/4 -20 M10x1.5 50 7/16-14 70 38 1-1/2 -24 M12x1.75 92 1/2-13 105 51 2 -32 M12x1.75 92 1/2-13 105 64 2-1/2 -40 M12x1.75 92 1/2-13 105 76 3 -48 M16x2 210 5/8-11 210 89 3-1/2 -56 M16x2 210 5/8-11 210 102 4 -64 M16x2 210 5/8-11 210 127 5 -80 M16x2 210 5/8-11 210 32 1-1/4 -20 - - 7/16-14 70 38 1-1/2 -24 - - 1/2-13 105 51 2 -32 - - 1/2-13 105 G Thread Assembly torque Tolerances: max. 10%; min. 0% G Thread Assembly torque Tolerances: max. 10%; min. 0% DN Inch Size metric Nm UNC (Inch) Nm G Thread Assembly torque Tolerances: max. 10%; min. 0% G Thread Assembly torque Tolerances: max. 10%; min. 0% DN Inch Size metric Nm UNC (Inch) Nm Technical handbook VII The correct method to fit ISO 6162-1 flange • Make sure sealing surfaces are free of burrs, nicks, scratches or any contamination • Lubricate the O-ring with system fluid or compatible lubricant • Position flange and clamp halves • Place lock washers on bolts and bolt through clamp halves • Hand tighten bolts • Torque bolts in diagonal sequence in small increments to the appropriate torque level listed in chart • Tighten bolts according to chart Spanner torque values ISO 6162-1 flange ISO 6162-1 flange 5000 psi The correct method to fit ISO 6162-1 flange Technical handbook
RkJQdWJsaXNoZXIy MzYzNzg=