96 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 BRASS NORMALLY CLOSED PIPE MOUNTING Port size Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. Valve Ref. Housing Ref. Coil Ref. Min Max(MOPD) Min Max BSP mm Kv l/min KV m3/h Qn l/min bar AC bar DC bar °C °C AC W DC W 1" 18 110 6.6 10150 0.3 12 12 -10 100 FKM 321K4706 2995 481865 8 9 2.1/3.0 7100 18 110 6.6 10150 0.3 12 12 -10 120 FKM 321K4706 4270 481000 8 8 2.1/3.0 7100 18 110 6.6 10150 0.3 12 12 -10 100 FKM 321K4756 1 2995 481865 8 9 2.1/3.0 7100 18 110 6.6 10150 0.3 12 12 -10 120 FKM 321K4756 1 4270 481000 8 8 2.1/3.0 7100 25 180 10.8 14000 0.3 16 16 -10 100 NBR E321G3710 2 2995 481865 8 9 2.0 3442 25 180 10.8 14000 0.3 16 16 -10 100 NBR E321G3710 2 4270 481000 8 8 2.0 3442 1 1/4" 28 280 16.8 18000 0.3 16 16 -10 100 NBR E321G3810 2 2995 481865 8 9 2.0 3442 28 280 16.8 18000 0.3 16 16 -10 100 NBR E321G3810 2 4270 481000 8 8 2.0 3442 1 1/2" 40 420 25.2 31500 0.3 16 7 -10 100 FKM E321G3910 2 2995 481865 8 9 2.0 3442 40 420 25.2 31500 0.3 16 8.5 -10 100 FKM E321G3910 2 4270 481000 8 8 2.0 3442 2" 40 540 32.4 40000 0.3 16 7 -10 100 FKM E321G4010 2 2995 481865 8 9 2.0 3442 40 540 32.4 40000 0.3 16 8.5 -10 100 FKM E321G4010 2 4270 481000 8 8 2.0 3442 Notes: 1.With manual override 2.With manual override and 4 position selector for controlled closure rate - without manual override and without 4 position selector on request: use same reference removing suffix '10', e.g. E321G36 2 WAY VALVES PILOT OPERATED ANTI WATER HAMMER VALVES 2/2
RkJQdWJsaXNoZXIy MzYzNzg=