76 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 BRASS NORMALLY CLOSED PIPE MOUNTING Port size (BSP) Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. Valve Ref. Housing Ref. Coil Ref. Min Max(MOPD) Min Max mm Kv l/min KV m3/h Qn m3/h bar AC bar DC bar °C °C AC W DC W 1/2" 11 36 2.16 2500 0.2 10 3 -10 100 NBR E321K15 2995 481865 8 9 2.0 3427 11 36 2.16 2500 0.2 10 10 -10 120 NBR E321K15 4270 486265 14 14 2.0 3427 11 36 2.16 2500 0.2 10 3 -10 100 FKM E321K25 2995 481865 8 9 2.0 3427 11 36 2.16 2500 0.2 4 4 -10 65 FKM E321K25 - 492070 9 8 2.0 3427 12 50 3 3400 0.3 10 10 -10 100 NBR 321K35 8993 481180 4 5 1.1 7093 12 50 3 3400 0.3 10 7 -10 75 NBR 321K35 8993 488980 2 2.5 1.1 7093 12 50 3 3400 0.3 12 12 -10 100 FKM 321K4506 2995 481865 8 9 2.1/3.0 7094 12 50 3 3400 0.3 12 12 -10 120 FKM 321K4506 4270 481000 8 8 2.1/3.0 7094 12 50 3 3400 0.3 12 12 -10 100 FKM 321K4556 1 2995 481865 8 9 2.1/3.0 7094 12 50 3 3400 0.3 12 12 -10 120 FKM 321K4556 1 4270 481000 8 8 2.1/3.0 7094 Notes: 1.With manual override 2 WAY VALVES PILOT OPERATED VALVES FOR WATER AND NEUTRAL LIQUIDS 2/2