46 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 BRASS NORMALLY CLOSED PIPE MOUNTING Port size (BSP) Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. Valve Ref. Housing Ref. Coil Ref. Min Max(MOPD) Min Max mm Kv l/min KV m3/h Qn m3/h bar AC bar DC bar °C °C AC W DC W 3/4" 15 60 3.6 3550 1.5 40 40 -10 50 PUR 321H36 2995 481865 8 9 2.1 3696 15 60 3.6 3550 1.5 40 40 -10 50 PUR 321H36 4270 481000 8 8 2.1 3696 18 100 6 9400 0.3 10 10 -10 100 NBR 321K36 8993 481180 4 5 1.1 7097 18 100 6 9400 0.3 10 7 -10 75 NBR 321K36 8993 488980 2 2.5 1.1 7097 18 100 6 9400 0.3 10 10 -10 100 FKM 321K3606 8993 481180 4 5 1.1 7097 18 100 6 9400 0.3 10 7 -10 75 FKM 321K3606 8993 488980 2 2.5 1.1 7097 20 135 8.1 9500 0.3 16 16 -10 100 NBR E321G36 2995 481865 8 9 2.0 3442 20 135 8.1 9500 0.3 16 16 -10 100 NBR E321G36 4270 481000 8 8 2.0 3442 20 135 8.1 9500 0.3 16 16 -10 100 FKM E321G3606 2995 481865 8 9 2.0/14.1 3442 20 135 8.1 9500 0.3 16 16 -10 120 FKM E321G3606 4270 481000 8 8 2.0/14.1 3442 20 135 8.1 9500 0.3 16 16 -10 120 FKM E321G3606 4270 486265 14 14 2.0/14.1 3442 2 WAY VALVES PILOT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 2/2