General Catalogue Solenoid Valves for Fluid Control

449 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 EXPLOSION PROOF ELECTRICAL PARTS NON ENCAPSULATED ELECTRICAL PARTS "nAc nCc" ELECTRICAL PART 32 mm To Order a Coil choose Coil Ref + Voltage Code, example: 495880 for 24 VDC = 495880C2 This coil can be mounted with every Parker ATEX solenoid valves corresponding to the specified Coil Group. See column "Coil Group" within valve pages. Application: Control of solenoid valves in dangerous areas where explosion-proof protection Ex nAc nCc IIC T3 is required. Ease of mounting in confined space - offers shock and corrosion protection - simplifies conversion of existing equipment to other requirements, etc. Benefits: The synthetic material encapsulation of the coil provides an effective compact housing, offering full protection against dust, oil, water, etc. Small size for ease of mounting in confined spaces. Specification 32 mm Coil "nAc nCc" Reference 495880 Certificate LCIE 05 ATEX 6003X Coil Group 2.0 / 2.2 Type of protection Gas II 3 G Ex nAc nCc IIC T3 Dust II 3 D - Ex tc IIIC - T195°C Degree of protection IP65 (with plug) according to IEC/EN 60529 Standards Insulation Class H 180°C Duty cycle 100% Ambiant temperature -40°C to +65°C The application is limited also by the temperature range of the valve. Elect. Power DC Pn (hot) 14 W P (cold) 20°C - AC Pn (holding) 14 W Attraction cold - Weight 180 g Voltages "Un" VAC/Hz Code VDC Code -10% to +10% of the Un 24/50 110/50 230/50 A2 A5 F4 24 C2 2.0/2.2 COIL GROUP ZONE 2/22

RkJQdWJsaXNoZXIy MzYzNzg=