42 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 Drawing 7094 BRASS NORMALLY CLOSED PIPE MOUNTING Port size (BSP) Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. Valve Ref. Housing Ref. Coil Ref. Min Max(MOPD) Min Max mm Kv l/min KV m3/h Qn m3/h bar AC bar DC bar °C °C AC W DC W 3/8" 11 50 3 2800 0.3 40 25 -10 100 NBR E321H13 124 2995 481865 8 9 2.0 3521 11 50 3 2800 0.3 40 30 -10 100 NBR E321H13 124 4270 481000 8 8 2.0 3521 11 50 3 2800 0.3 40 40 -10 100 NBR E321H13 124 4270 486265 14 14 2.0 3521 11 36 2.16 2500 0.2 10 4 -10 100 NBR E321K13 4270 481000 8 8 2.0 3429 11 36 2.16 2500 0.2 10 10 -10 100 NBR E321K13 4270 486265 14 14 2.0 3429 11 36 2.16 2500 0.2 10 - -10 100 NBR E321K1314 2995 483466 8-11 - 2.0 3429 11 36 2.16 2500 0.2 10 10 -10 100 NBR E321K1314 4270 486265 14 14 2.0 3429 12 45 2.7 3050 0.3 10 10 -10 100 NBR 321K33 8993 481180 4 5 1.1 7093 12 45 2.7 3050 0.3 10 7 -10 75 NBR 321K33 8993 488980 2 2.5 1.1 7093 12 45 2.7 3050 0.3 10 10 -10 100 FKM 321K3306 1 8993 481180 4 5 1.1 7093 12 45 2.7 3050 0.3 10 7 -10 75 FKM 321K3306 1 8993 488980 2 2.5 1.1 7093 12 45 2.7 3050 0.3 12 12 -10 100 FKM 321K4356 3 2995 481865 8 9 2.1/3.0 7094 12 45 2.7 3050 0.3 12 12 -10 120 FKM 321K4356 3 4270 481000 8 8 2.1/3.0 7094 Notes: 1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing 2.Pilot seat disc in synthetic Ruby 3.Valve with manual override 4.With 4 position selector for controlled closure rate 2 WAY VALVES PILOT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 2/2