40 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 Drawing 7094 BRASS NORMALLY CLOSED PIPE MOUNTING Port size (BSP) Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. Valve Ref. Housing Ref. Coil Ref. Min Max(MOPD) Min Max mm Kv l/min KV m3/h Qn m3/h bar AC bar DC bar °C °C AC W DC W 1/4" 8 36 2.16 1600 0.3 40 25 -10 100 NBR E321H11 124 2995 481865 8 9 2.0 3523 8 36 2.16 1600 0.3 40 30 -10 100 NBR E321H11 124 4270 481000 8 8 2.0 3523 8 36 2.16 1600 0.3 40 40 -10 100 NBR E321H11 124 4270 486265 14 14 2.0 3523 11 28 1.68 1800 0.2 10 3 -10 100 NBR E321K10 2995 481865 8 9 2.0 3429 11 28 1.68 1800 0.2 10 4 -10 100 NBR E321K10 4270 481000 8 8 2.0 3429 12 30 1.8 2150 0.3 10 10 -10 100 NBR 321K31 8993 481180 4 5 1.1 7093 12 30 1.8 2150 0.3 10 7 -10 75 NBR 321K31 8993 488980 2 2.5 1.1 7093 12 30 1.8 2150 0.3 10 10 -10 100 FKM 321K3106 8993 481180 4 5 1.1 7093 12 30 1.8 2150 0.3 10 7 -10 75 FKM 321K3106 8993 488980 2 2.5 1.1 7093 12 32 1.92 2150 0.3 12 12 -10 100 FKM 321K4156 3 2995 481865 8 9 2.1/3.0 7094 12 32 1.92 2150 0.3 12 12 -10 120 FKM 321K4156 3 4270 481000 8 8 2.1/3.0 7094 Notes: 1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing 2.Pilot seat disc in synthetic Ruby 3.Valve with manual override 4.With 4 position selector for controlled closure rate 2 WAY VALVES PILOT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 2/2
RkJQdWJsaXNoZXIy MzYzNzg=