332 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 ANODIZED ALUMINIUM SOLENOID OPERATED - SPRING RETURN NAMUR Port size Orifice Ø Flow factor Operating Pressure Differential Fluid Temp. Seat Seal ATEX Zone Protection Mode Power Coil Group Dwg. No. 1 Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max BSP mm Qn l/min bar AC bar DC bar °C °C AC W DC W 1/8''- 1/4'' 4 355 2 - 10 -10 55 NBR 341L9594 1 2995 483580.01 0-20 Ex ia IIC T6 - 0.5 to 3 7.0 3992 4 355 1 - 10 -10 75 NBR 341L9594 1 - 495910 0-20 Ex ia IIC T4 to T6 - 0.3 to 3 7.0 3992 4 355 2 - 10 -10 75 NBR/PUR 341L9597 2 2995 482740 - - - 1.6 6.0/8.0 8025 4 355 2 10 10 -10 75 NBR/PUR 341L9597 2 - 495900 1-21 Ex d mb IIC T4 to T6 2.5 2 6.0/8.0 8025 4 355 2 - 10 -10 75 NBR/PUR 341L9597 2 - 495910 0-20 Ex ia IIC T4 to T6 - 0.3 to 3 6.0/8.0 8025 4 355 2 - 10 -10 75 NBR/PUR 341L9597 2 2995 496125 2-22 Ex nAC IIC T5/T6 - 1.6 6.0/8.0 8025 4 355 2 - 10 -25 55 NBR/PUR 341L9598 2995 483580.01 0-20 Ex ia IIC T6 - 0.5 to 3 7.0 3992 Notes: 1.Pilot seat in FKM 2.With manual override 3 & 5 WAY PNEUMATIC DISTRIBUTORS PILOT OPERATED 3 & 5 WAY PNEUMATIC VALVES FOR ACTUATOR CONTROL (NAMUR) 3/2-5/2