326 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 ANODIZED ALUMINIUM W1 CLOSED CENTER POSITION NAMUR Port size Orifice Ø Flow factor Operating Pressure Differential Fluid Temp. Seat Seal ATEX Zone Protection Mode Power Coil Group Dwg. No. 1 Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max BSP mm Qn l/min bar AC bar DC bar °C °C AC W DC W 1/8''- 1/4'' 4 400 2 10 10 -25 80 NBR 342N11 12 - 482606 1-21 Ex mb IIC T4/T5 2 2.5 1.1 7305 4 400 2 10 10 -25 80 NBR 342N11 12 8993 488980 - - 2 2.5 1.1 7305 1/4'' 4 400 2 - 10 -10 65 NBR 342N3197 2 - 495910 0-20 Ex ia IIC T4 to T6 - 0.3 to 3 6.0/8.0 7297 4 400 2 - 10 -10 55 NBR 342N319723 2995 483580.01 0-20 Ex ia IIC T6 - 0.5 to 3 6.0/7.0/8.0 7297 7 1250 3 10 10 -20 50 NBR 342N03 2 - 496131 - - 3 3 1.2 8057 7 1250 3 10 10 -20 50 NBR 342N03 2 - 496482 - - 3 3 1.2 8057 7 1250 3 10 10 -10 50 NBR 342N03 2 - 496637 22 Ex tD A22 IP65 - T95°C 3 3 1.2 8057 7 1250 2.5 10 10 -20 50 NBR 342N33 2 2995 481865 - - 8 9 2.1 8209 7 1250 2.5 10 10 -20 50 NBR 342N33 2 2995 495870 2-22 Ex nAC IIC T3/T4 8 9 2.1 8209 7 1250 2.5 10 10 -20 50 NBR 342N33 2 - 495905 1-21 Ex d mb IIC T4 8 8 2.1 8209 Notes: 1.With captured exhaust 2.With manual override 3.A minimum current of 65 mA is required with this coil configuration Drawing 8209 3 & 5 WAY PNEUMATIC DISTRIBUTORS PILOT OPERATED 3 & 5 WAY PNEUMATIC VALVES FOR ACTUATOR CONTROL (NAMUR) 5/3