294 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 ANODIZED ALUMINIUM DUAL SOLENOIDS PIPE MOUNTING Port size Orifice Ø Flow factor Operating Pressure Differential Fluid Temp. Seat Seal ATEX Zone Protection Mode Power Coil Group Dwg. No. 1 Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max BSP mm Qn l/min bar AC bar DC bar °C °C AC W DC W 1/4'' 7 1250 2.5 10 10 -10 50 NBR 347P03 2 - 496131 - - 3 3 1.2 8222 7 1250 2.5 10 10 -10 50 NBR 347P03 2 - 496482 - - 3 3 1.2 8222 7 1250 2.5 10 10 -10 50 NBR 347P03 2 - 496637 22 Ex tD A22 IP65 - T95°C 3 3 1.2 8222 7 1250 2.5 10 10 -10 50 NBR 347P33 2 2995 481865 - - 8 9 2.1 8223 7 1250 2.5 10 10 -10 50 NBR 347P33 2 2995 495870 2-22 Ex nAC IIC T3/T4 8 9 2.1 8223 7 1250 2.5 10 10 -10 50 NBR 347P33 2 - 495905 1-21 Ex d mb IIC T4 8 8 2.1 8223 8 1400 2 10 10 -25 80 NBR 347P02 2 - 482606 1-21 Ex mb IIC T4/T5 2 2.5 1.1 7316 8 1400 2 10 10 -25 80 NBR 347P02 2 8993 488980 - - 2 2.5 1.1 7316 8 1400 2 10 10 -25 80 NBR 347P22 2 2995 481865 - - 8 9 2.1 7321 8 1400 2 10 10 -25 80 NBR 347P22 2 4270 481000 - - 8 8 2.1 7321 Notes: 1.Pilot seat in FKM 2.With manual override 3. A minimum current of 65 mA is required with this coil configuration Drawing 7321 3 & 5 WAY PNEUMATIC DISTRIBUTORS PILOT OPERATED 3 & 5 WAY PNEUMATIC VALVES FOR ACTUATOR CONTROL (PIPE MOUNTING) 5/2