292 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 ANODIZED ALUMINIUM DUAL SOLENOIDS PIPE MOUNTING Port size Orifice Ø Flow factor Operating Pressure Differential Fluid Temp. Seat Seal ATEX Zone Protection Mode Power Coil Group Dwg. No. 1 Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max BSP mm Qn l/min bar AC bar DC bar °C °C AC W DC W 1/8'' 4 400 2 10 10 -25 80 NBR 347P01 2 - 482606 1-21 Ex mb IIC T4/T5 2 2.5 1.1 7306 4 400 2 10 10 -25 80 NBR 347P01 2 8993 488980 - - 2 2.5 1.1 7306 4 400 2 10 10 -25 80 NBR 347P21 12 2995 481865 - - 8 9 2.1 7298 4 400 2 10 10 -25 80 NBR 347P21 12 4270 481000 - - 8 8 2.1 7298 4 400 2 - 10 -25 55 NBR 347P2190 2995 483580.01 0-20 Ex ia IIC T6 - 0.5 to 3 7.0 7353 4 400 2 - 10 -25 75 NBR 347P2190 - 488660.01 0-20 Ex ia IIC T6 - 0.3 to 3 7.0 7353 4 400 2 - 10 -25 75 NBR 347P2190 - 495910 0-20 Ex ia IIC T4 to T6 - 0.3 to 3 7.0 7353 4 400 2 - 10 -20 65 NBR/ PUR 347P2197 2 2995 482740 - - - 1.6 6.0/8.0 8028 4 400 2 10 10 -20 65 NBR/ PUR 347P2197 2 - 495900 1-21 Ex d mb IIC T4 to T6 2.5 2 6.0/8.0 8028 4 400 2 - 10 -20 65 NBR/ PUR 347P2197 2 - 495910 0-20 Ex ia IIC T4 to T6 - 0.3 to 3 6.0/8.0 8028 4 400 2 - 10 -20 65 NBR/ PUR 347P2197 2 2995 496125 2-22 Ex nAC IIC T5/T6 - 1.6 6.0/8.0 8028 4 400 2 - 10 -20 55 NBR/ PUR 347P2197 23 2995 483580.01 0-20 Ex ia IIC T6 - 0.5 to 3 6.0/7.0/8.0 8028 Notes: 1.Pilot seat in FKM 2.With manual override 3. A minimum current of 65 mA is required with this coil configuration Drawing 8028 3 & 5 WAY PNEUMATIC DISTRIBUTORS PILOT OPERATED 3 & 5 WAY PNEUMATIC VALVES FOR ACTUATOR CONTROL (PIPE MOUNTING) 5/2
RkJQdWJsaXNoZXIy MzYzNzg=