252 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 ANODIZED ALUMINIUM SPRING RETURN SUB-BASE MOUNTING Port size Orifice Ø Flow factor Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. 1 Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max mm Qn l/min bar AC bar DC bar °C °C AC W DC W SB 6 630 1 10 10 -10 75 NBR 341F34 12 2995 481865 8 9 2.1 3287 6 630 1 10 10 -10 75 NBR 341F34 12 4270 481000 8 8 2.1 3287 6 630 1 10 10 -10 75 NBR 341F34032 2995 481865 8 9 2.1 3287 6 630 1 10 10 -10 75 NBR 341F34032 4270 481000 8 8 2.1 3287 6 630 1 10 10 -25 75 NBR 341F344012 2995 481865 8 9 2.1 3287 Notes: 1.With flow regulator 2. With manual override ANODIZED ALUMINIUM CONTROL BY ELECTRIC IMPULSE SUB-BASE MOUNTING Port size Orifice Ø Flow factor Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. 1 Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max mm Qn l/min bar AC bar DC bar °C °C AC W DC W SB 6 630 1 10 - -10 75 NBR 345F34 1 4269 484990 11 - 4.0 3287 6 630 1 - 10 -10 75 NBR 345F34 1 4269 485400 - 13 4.0 3287 Notes: 1.With flow regulator e manual override 5 WAY VALVES PILOT OPERATED 5 WAY PNEUMATIC DISTRIBUTORS (PIPE MOUNTING/SUB-BASE MOUNTING) 5/2
RkJQdWJsaXNoZXIy MzYzNzg=