202 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 ANODIZED ALUMINIUM NORMALLY CLOSED PIPE MOUNTING Port size Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal IS Power Coil Group Dwg. No. 1 (2) 1 (2) 1 (2) Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max BSP mm Kv l/min Q l/min bar AC bar DC bar °C °C AC W DC W 1/4" 6.5 6.5 10 - 645 - 1 - 10 -10 55 NBR 331B7490 1 2995 48358001 * - 0.5-3 7.0/8.0 8270 6.5 6.5 10 - 645 - 1 - 10 -10 75 NBR 331B7490 1 - 495910 * - 0.3- 1.2 7.0/8.0 8270 6.5 6.5 10 - 750 - 1 10 10 -10 75 NBR E331B74 13 2995 481865 8 9 2.1 3240 6.5 6.5 10 - 750 - 1 10 10 -10 75 NBR E331B74 13 4270 485100 8 8 2.1 3240 8 8 20 20 1100 1100 1 15 15 -10 75 NBR E331B01 2 4270 481000 8 8 2.1 3234 8 8 20 20 1100 1100 1 15 15 -10 75 NBR E331B01 2 2995 481865 8 9 2.1 3234 8 8 20 20 1100 1100 1 15 15 -10 65 NBR E331B01 2 - 483371 8 8 2.1 3234 Notes: 1.Valve only compatible with air and neutral gases 2.Valve only compatible with hydraulic oil and air/neutral gases 3.With manual override 3 WAY VALVES PILOT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 3/2