General Catalogue Solenoid Valves for Fluid Control

190 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 BRASS UNIVERSAL SUB-BASE MOUNTING Port size Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. 1 (2) 1 (2) 1 (2) Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max mm Kv l/min KV m3/h bar AC bar DC bar °C °C AC W DC W SB 1.5 1.5 1.5 1.5 0.09 0.09 0 10 10 -10 100 FKM E133F4450 1 4270 481000 8 8 2.1 3509 1.5 1.5 1.5 1.5 0.09 0.09 0 10 10 -10 120 FKM E133F4450 1 2995 481865 8 9 2.1 3509 1.5 1.5 1.5 1.5 0.09 0.09 0 10 10 -10 120 FKM E133F44 4270 481000 8 8 2.1 3509 1.5 1.5 1.5 1.5 0.09 0.09 0 10 10 -10 100 FKM E133F44 2995 481865 8 9 2.1 3509 2 2 2.5 2.5 0.15 0.15 0 7 7 -10 120 FKM 133F46 4270 481000 8 8 2.1 3509 2 2 2.5 2.5 0.15 0.15 0 7 7 -10 100 FKM 133F46 2995 481865 8 9 2.1 3509 2.5 2.5 3.5 3.5 0.21 0.21 0 4 4 -10 120 FKM E133F43 4270 481000 8 8 2.1 3509 2.5 2.5 3.5 3.5 0.21 0.21 0 4 4 -10 100 FKM E133F43 2995 481865 8 9 2.1 3509 Notes: 1.With manual override 3 WAY VALVES DIRECT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 3/2

RkJQdWJsaXNoZXIy MzYzNzg=