186 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 Drawing 8022 BRASS NORMALLY CLOSED SUB-BASE MOUNTING Port size Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal IS Power Coil Group Dwg. No. 1 (2) 1 (2) 1 (2) Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max mm Kv l/min KV m3/h bar AC bar DC bar °C °C AC W DC W SB 1.2 1.5 0.7 0.9 0.04 0.05 0 10 10 -10 75 FKM 131M75 8993 488980 2 2.5 1.1 3383 1.2 1.5 0.7 0.9 0.04 0.05 0 10 10 -10 75 FKM 131M7550 1 8993 488980 2 2.5 1.1 3383 1.5 1.5 0.9 0.9 0.05 0.05 0 7 7 -10 75 FKM 131M74 8993 488980 2 2.5 1.1 3383 1.5 1.5 0.9 0.9 0.05 0.05 0 7 7 -10 75 FKM 131M7450 1 8993 488980 2 2.5 1.1 3383 SB 1 1 0.6 0.6 0.04 0.036 0 - 10 -10 55 FKM 131F4490 2995 48358001 * - 0.5-3 7.0 7057 1 1 0.6 0.6 0.04 0.036 0 - 10 -10 75 FKM 131F4490 - 495910 * - 0.3- 1.2 7.0 7057 1.5 2 1.5 2.2 0.09 0.13 0 - 16 -10 100 FKM 131F4410 2995 481865 - 9 2.1 3509 1.5 1.5 1.5 1.5 0.09 0.09 0 - 7 -20 75 PUR 131F4497 2995 482740 - 1.6 6.0/8.0 8022 1.5 1.5 1.5 1.5 0.09 0.09 0 7 7 -20 75 PUR 131F4497 - 495900 2.5 2 6.0/8.0 8022 1.5 1.5 1.5 1.5 0.09 0.09 0 - 7 -20 75 PUR 131F4497 - 495910 * - 0.3- 1.2 6.0/8.0 8022 1.5 1.5 1.5 1.5 0.09 0.09 0 - 7 -20 65 PUR 131F4497 2995 496125 - 1.6 6.0/8.0 8022 Notes: 1.With manual override 3 WAY VALVES DIRECT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 3/2