180 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 BRASS NORMALLY OPEN PIPE MOUNTING Port size Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. 1 (2) 1 (2) 1 (2) Valve Ref. Housing Ref. Coil Ref. Min Max (MOPD) Min Max BSP mm Kv l/min KV m3/h bar AC bar DC bar °C °C AC W DC W 1/4" 1.5 1.5 1.4 1.4 0.08 0.08 0 16 16 -10 120 FKM 132K04 4270 481000 8 8 2.1 3510 1.5 1.5 1.4 1.4 0.08 0.08 0 16 16 -10 100 FKM 132K04 2995 481865 8 9 2.1 3510 2 2 1.8 1.8 0.11 0.11 0 10 10 -10 120 FKM 132K06 4270 481000 8 8 2.1 3510 2 2 1.8 1.8 0.11 0.11 0 10 10 -10 100 FKM 132K06 2995 481865 8 9 2.1 3510 2 3 2.5 4.5 0.15 0.27 0 10 5 -10 75 FKM 132T23 4270 481000 8 8 2.0 3223 2 3 2.5 4.5 0.15 0.27 0 10 5 -10 75 FKM 132T23 2995 481865 8 9 2.0 3223 2 3 2.5 4.5 0.15 0.27 0 - 10 -10 75 FKM 132T23 4270 486265 - 14 2.0 3223 2 3 2.5 4.5 0.15 0.27 0 10 5 -10 75 FKM 132T2301 1 4270 481000 8 8 2.0 3223 2 3 2.5 4.5 0.15 0.27 0 10 5 -10 75 FKM 132T2301 1 2995 481865 8 9 2.0 3223 2 3 2.5 4.5 0.15 0.27 0 - 10 -10 75 FKM 132T2301 1 4270 486265 - 14 2.0 3223 2.5 2.5 2.2 2.2 0.13 0.13 0 7 7 -10 120 FKM 132K03 4270 481000 8 8 2.1 3510 2.5 2.5 2.2 2.2 0.13 0.13 0 7 7 -10 100 FKM 132K03 2995 481865 8 9 2.1 3510 3 4 4.5 6 0.27 0.36 0 10 - -10 75 FKM 132T22 4270 481044 14 - 2.2 3223 3 4 4.5 6 0.270.36 0 7 - -10 75 FKM 132T22 2995 492425 14 - 2.2 3223 Notes: 1.With manual override 3 WAY VALVES DIRECT OPERATED VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 3/2
RkJQdWJsaXNoZXIy MzYzNzg=