171 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 3 WAY VALVES VALVES FOR DRY OR LUBRICATED AIR, NEUTRAL GASES AND LIQUIDS 3/2 Oil Water Air Actuation Body Function Port Size Orifice (mm) Flow Factor Kv(l/min) MOPD (bar) Max Fluid Temp. (°C) Page Parker Valves Direct Operated Brass/Pipe Mounting Normally Closed 1/8" 1.2 to 2.5 3.5 15 120 172 1/4" 1 to 4.5 7 15 120 172 to 178 Normally Open 1/4" 1.5 to 3 4.5 16 120 180 Universal 1/8" 1.5 to 2.5 3.5 10 140 182 1/4" 0.8 to 3 4.5 30 140 182 and 184 Control by Electric Impulse 1/4" 1.5 1.5 16 100 184 Brass/Sub-base Mounting Normally Closed SB 1 to 2.5 3.5 15 140 186 and 188 Normally Open SB 1.5 to 2.5 2.2 15 120 188 Universal SB 1.5 to 2.5 2.5 10 120 190 Anodized Aluminium/ Banjo Normally Closed 1/8" 1.2 - 10 50 192 1/4" 1.2 - 10 50 192 316L Stainless St./Subbase Mounting Normally Closed SB 1.5 1.5 15 100 194 POM/Sub-base Mounting Normally Closed SB 2 2 10 50 196 Stainless St./Sub-base Mounting Normally Closed SB 1.5 to 5 7.2 14 140 198 Universal SB 1.5 to 3 3.3 9.5 140 200 Pilot Operated Anodized Aluminium/ Pipe Mounting Normally Closed 1/4" 6.5 to 8 20 15 75 202 1/2" 14 - 15 75 204 Normally Open 1/4" 8 20 40 75 204 1/2" 14 - 15 75 206 Anodized Aluminium/ Sub-base Mounting/ Poppet Normally Closed SB 15 - 10 75 206
RkJQdWJsaXNoZXIy MzYzNzg=