118 Parker Hannifin Corporation Fluid Control Solutions Europe General Catalogue FCSE/0112/UK V2.2 07/2022 BRASS NORMALLY CLOSED PIPE MOUNTING Port size Orifice Ø Flow factors Operating Pressure Differential Fluid Temp. Seat Seal Power Coil Group Dwg. No. Valve Ref. Housing Ref. Coil Ref. Min Max(MOPD) Min Max BSP mm Kv l/min KV m3/h Qn l/min bar AC bar DC bar °C °C AC W DC W 1/4" 8 36 2.16 1600 0.3 40 25 -10 100 NBR E321H11 12 2995 481865 8 9 2.0 3523 8 36 2.16 1600 0.3 40 30 -10 100 NBR E321H11 12 4270 481000 8 8 2.0 3523 8 36 2.16 1600 0.3 40 40 -10 100 NBR E321H11 12 4270 486265 14 14 2.0 3523 8 36 2.16 - 0.3 40 25 -10 100 FKM E321H21 12 2995 481865 8 9 2.0 3523 8 36 2.16 - 0.3 40 30 -10 120 FKM E321H21 12 4270 481000 8 8 2.0 3523 8 36 2.16 - 0.3 40 40 -10 140 FKM E321H21 12 4270 486265 14 14 2.0 3523 3/8" 11 50 3 2800 0.3 40 25 -10 100 NBR E321H13 12 2995 481865 8 9 2.0 3521 11 50 3 2800 0.3 40 30 -10 100 NBR E321H13 12 4270 481000 8 8 2.0 3521 11 50 3 2800 0.3 40 40 -10 100 NBR E321H13 12 4270 486265 14 14 2.0 3521 11 50 3 - 0.3 40 25 -10 100 FKM E321H23 12 2995 481865 8 9 2.0 3521 11 50 3 - 0.3 40 30 -10 120 FKM E321H23 12 4270 481000 8 8 2.0 3521 11 50 3 - 0.3 40 40 -10 140 FKM E321H23 12 4270 486265 14 14 2.0 3521 11 36 2.16 - 0.2 20 3 -10 100 Ruby E321K63 2995 483510 9 - 2.0 3429 11 36 2.16 - 0.2 30 4 -10 140 Ruby E321K63 4270 488553 9 - 2.0 3429 11 36 2.16 - 0.2 4 4 -10 75 Ruby E321K63 - 492190 11 9 2.0 3429 Notes: 1.Minimum pressure differential = 0.3 bar for opening and 0 bar for closing 2.Pilot seat disc in synthetic Ruby 2 WAY VALVES PILOT OPERATED VALVES FOR HYDRAULIC OIL AND NEUTRAL LIQUIDS (UP TO 100 BAR) 2/2