92 www.parker.com/gsfe Condensate Management Technical Data Drain Type Drain Models Minimum Operating Pressure Maximum Operating Pressure Minimum Operating Temperature Maximum Operating Temperature bar g psi g bar g psi g °C °F °C °F External Float HDF120 - 220 1 15 16 232 2 35 60 140 Electronic Level Sensing ED3002 - ED3100 1 15 16 232 2 35 60 140 Electronic Level Sensing ED4100 16 232 50 725 2 35 50 122 Stated flows are for operation at max operating pressure shown above, ambient air 25°C (77°F) / 60% RH, compressor discharge temperature 35°C (95°F), refrigeration dryer pressure dewpoint +3°C, with reference to 20°C, 1 bar (a), 0% relative water vapour pressure. Refrigeration dryer and filter flow rates assume adequate condensate drainage upstream. Flow Rates - Zero Air Loss External Float Drains Model Pipe Size Compressed Air Flow Rate Electrical Supply Inlet Outlet L/S m³/min m³/hr cfm HDF120-A 1/2" 1/2" 1500 90 5400 3178 - HDF180-A 1" 1/2" 1667 100 6000 3532 - HDF220-A 1" 1/2" 4167 251 15000 8829 - External float drain (with built-in air vent) HDF120 1/2" 1/2" 1500 90 5400 3178 - HDF180 1" 1/2" 1667 100 6000 3532 - HDF220 1" 1/2" 4167 251 15000 8829 - External float drain (without air vent) HDF220BE 1" 1/2" 1806 109 6500 3826 - External float drains BioEnergy Model Pipe Size Compressed Air Flow Rate (Aftercooler / Air Receiver) Compressed Air Flow Rate (Refrigeration Dryer) Compressed Air Flow Rate (Filter) Electrical Supply Inlet Outlet L/S m³/min m³/hr cfm L/S m³/min m³/hr cfm L/S m³/min m³/hr cfm ED3002-G230 1 x G G3/8 - - - - - - - - 200 12 720 424 230/1/50-60 ED3004-G230 1 x G G3/8 67 4 240 141 133 8 480 283 667 40 2400 1413 230/1/50-60 ED3007-G230 2 x G G3/8 117 7 420 247 233 14 840 494 1167 70 4200 2472 230/1/50-60 ED3030-G230 2 x G G3/8 500 30 1800 1059 1000 60 3600 2119 5000 301 18000 10595 230/1/50-60 ED3100-G230 2 x G G3/8 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 230/1/50-60 230V/1PH/50-60Hz - 16 bar g (232 psi g) ED3007-G24D 2 x G G3/8 117 7 420 247 233 14 840 494 1167 70 4200 2472 24V DC ED3030-G24D 2 x G G3/8 500 30 1800 1059 1000 60 3600 2119 5000 301 18000 10595 24V DC ED3100-G24D 2 x G G3/8 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 24V DC 24V DC - 16 bar g (232 psi g) ED4100/50-G230 G G 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 230/1/50-60 230V/1PH/50-60Hz - 50 bar g (725 psi g) ED4100/50-G24D G G 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 24V DC 24V DC - 50 bar g (725 psi g) Flow Rates - Zero Air Loss Electronic Level Sensing Drains HDF & ED Level Sensing Condensate Drains
RkJQdWJsaXNoZXIy MTQ4NTgyMQ==