GSFE CATALOGUE

66 www.parker.com/gsfe Modular Aluminium Compressed Air Dryers KE-MT Large Flow Heatless Adsorption Dryers Technical Data Dryer Models Minimum Operating Pressure Maximum Operating Pressure Minimum Operating Temperature Maximum Operating Temperature Maximum Ambient Temperature Electrical Supply (Standard) Electrical Supply (Optional) Thread Type Noise Level bar g psi g bar g psi g °C °F °C °F °C °F dB(A) KE-MT 120 - 600 4 58 10* 145 5 41 50 122 50 122 230V 1ph 50Hz/60Hz 115V 1ph 50/60Hz Flange < 120 *Higher operating pressures on request. CFOD - Correction Factor Outlet Dewpoint Outlet Dewpoint °C -25 -40 -70 °F -13 -40 -100 Correction Factor 1.00 1.00 2.00 CFIT - Correction Factor Maximum Inlet Temperature Maximum Inlet Temperature °C 25 30 35 40 45 50 °F 77 86 95 104 113 122 Correction Factor 0.94 0.95 1.00 1.15 1.22 1.28 CFAT - Correction Factor Maximum Ambient Temperature Maximum Ambient Temperature °C 25 30 35 40 45 50 °F 77 86 95 104 113 122 Correction Factor 1.00 1.00 1.00 1.00 1.00 1.00 CFMIP - Correction Factor Minimum Inlet Pressure Minimum Inlet Pressure bar g 4 5 6 7 8 9 10 psi g 58 73 87 100 116 131 145 Correction Factor 1.60 1.33 1.12 1.00 0.88 0.79 0.76 Product Selection & Correction Factors For correct operation, compressed air dryers must be sized using for the maximum (summer) inlet temperature, maximum (summer) ambient temperature, minimum inlet pressure, required outlet dewpoint and maximum flow rate of the installation. To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow rate equal to or above the MDC. Minimum Drying Capacity = System Flow x CFIT x CFAT x CFMIP x CFOD Flow Rates Model Pipe Size Inlet Flow Rate L/s m3/min m3/hr cfm KE-MT 120 DN 50 333 20 1200 706 KE-MT 150 DN 65 430 26 1550 912 KE-MT 200 DN 65 556 33 2000 1177 KE-MT 250 DN 80 695 42 2500 1472 KE-MT 300 DN 80 833 50 3000 1766 KE-MT 380 DN 100 1056 63 3800 2237 KE-MT 500 DN 100 1347 81 4850 2855 KE-MT 600 DN 125 1695 102 6100 3590 Dryer Performance Dryer Models Dewpoint (Standard) ISO8573-1:2010 Classification (Standard) Dewpoint (Option 1) ISO8573-1:2010 Classification (Option 1) Dewpoint (Option 2) ISO8573-1:2010 Classification (Option 2) °C °F °C °F °C °F KE-MT 120 - 600 -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2 ISO8573-1 Classifications when used with Parker OIL-X pre/post filtration. Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure. For flows at other pressures, apply the correction factors shown below. Dryers for smaller flows are available on request. Carbon Steel Twin Tower Compressed Air Dryers

RkJQdWJsaXNoZXIy MTQ4NTgyMQ==