GSFE CATALOGUE

52 www.parker.com/gsfe Modular Aluminium Compressed Air Dryers Flow Rates Model Pipe Size Inlet Flow Rate L/s m3/min m3/hr cfm CDAS HL 050 ATEX 1/2" 15 0.92 55 32 CDAS HL 055 ATEX 1/2" 19 1.17 70 41 CDAS HL 060 ATEX 1/2" 25 1.50 90 53 CDAS HL 065 ATEX 1/2" 31 1.84 110 65 CDAS HL 070 ATEX 3/4" 42 2.51 150 88 CDAS HL 075 ATEX 1" 51 3.09 185 109 CDAS HL 080 ATEX 1" 61 3.67 220 129 CDAS HL 085 ATEX 11/2" 83 5.01 300 177 Dryer Performance Dryer Models Dewpoint (Standard) ISO8573-1:2010 Classification (Standard) °C °F CDAS HL ATEX -40 -40 Class 2.2.2 ISO8573-1 Classifications when used with OIL-X pre/post filtration. Technical Data Dryer Models Minimum Operating Pressure Maximum Operating Pressure Minimum Operating Temperature Maximum Operating Temperature Maximum Ambient Temperature Electrical Supply Thread Type Noise Level bar g psi g bar g psi g °C °F °C °F °C °F dB(A) CDAS HL ATEX 4 58 16 232 5 41 50 122 55 131 Not Applicable - Fully Pneumatic Operation BSPP or NPT <75 Outlet Dewpoint °C -20 -40 -70 °F -4 -40 -100 Correction Factor 0.91 1.00 2.00 Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure. For flows at other pressures, apply the correction factors shown below. Maximum Inlet Temperature °C 25 30 35 40 45 50 °F 77 86 95 104 113 122 Correction Factor 1.00 1.00 1.00 1.04 1.14 1.37 Maximum Ambient Temperature °C 25 30 35 40 45 50 °F 77 86 95 104 113 122 Correction Factor 1.00 1.00 1.00 1.00 1.00 1.00 Minimum Inlet Pressure bar g 4 5 6 7 8 910111213141516 psi g 58 73 87 100 116 131 145 160 174 189 203 218 232 Correction Factor 1.60 1.33 1.14 1.00 0.89 0.80 0.73 0.67 0.62 0.57 0.53 0.50 0.47 Product Selection & Correction Factors For correct operation, compressed air dryers must be sized using for the maximum (summer) inlet temperature, maximum (summer) ambient temperature, minimum inlet pressure, required outlet dewpoint and maximum flow rate of the installation. To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow rate equal to or above the MDC. Minimum Drying Capacity = System Flow x CFMIT x CFMAT x CFMIP x CFOD CDAS HL ATEX Medium Flow Heatless Adsorption Dryers CFMIT - Correction Factor Maximum Inlet Temperature CFMAT - Correction Factor Maximum Ambient Temperature CFMIP - Correction Factor Minimum Inlet Pressure CFOD - Correction Factor Outlet Dewpoint

RkJQdWJsaXNoZXIy MTQ4NTgyMQ==