GSFE CATALOGUE

151 EnOxy Temperature Oxygen flow rate correction factor for EnOxy at various product concentrations1) 28% 30% 32% 34% 36% 38% 40% 5ºC (41°F) 0.76 0.76 0.76 0.76 0.76 0.76 0.76 10ºC (50°F) 0.84 0.84 0.84 0.84 0.84 0.84 0.84 15ºC (59°F) 0.91 0.91 0.91 0.91 0.91 0.91 0.91 25ºC (77°F) 1.09 1.09 1.09 1.09 1.09 1.09 1.09 30°C (86°F) 1.19 1.19 1.19 1.19 1.19 1.19 1.19 35ºC (95°F) 1.30 1.30 1.30 1.30 1.30 1.30 1.30 40ºC (104°F) 1.42 1.42 1.42 1.42 1.42 1.42 * 45ºC (113°F) 1.54 1.54 1.54 1.54 1.54 1.54 * 50ºC (122°F) 1.68 1.68 1.68 1.68 1.68 * * Table 1 Table 2 Temperature Feed-Air consumption correction factor for EnOxy at various product concentrations1) 28% 30% 32% 34% 36% 38% 40% 5ºC (41°F) 0.70 0.70 0.70 0.70 0.70 0.70 0.70 10ºC (50°F) 0.79 0.79 0.79 0.79 0.79 0.79 0.79 15ºC (59°F) 0.89 0.89 0.89 0.89 0.89 0.89 0.89 25ºC (77°F) 1.12 1.12 1.12 1.12 1.12 1.12 1.12 30°C (86°F) 1.25 1.25 1.25 1.25 1.25 1.25 1.25 35ºC (95°F) 1.38 1.38 1.38 1.38 1.38 1.38 1.38 40ºC (104°F) 1.53 1.53 1.53 1.53 1.53 1.53 * 45ºC (113°F) 1.68 1.68 1.6 8 1.68 1.68 1.68 * 50ºC (122°F) 1.83 1.83 1.83 1.83 1.83 * * 1) These numbers are indicative. *) No enriched oxygen can be generated at this temperature/oxygen % combination. Sizing conditions Inlet pressure 7 barg Oxygen purity 34% Feed-air temperature 30ºC O2 correction factor 1.19 (table 1) Feed-air correction factor 1.25 (table 2) Module EnOxy 608 O2 flow rate EnOxy608 251 l/hr (at 20ºC) Feed-air consumption EnOxy608 494 l/hr (at 20ºC) Example Corrected Oxygen Flow Calculation at 30ºC and 34% Corrected oxygen flow: 251 l/hr x 1.19 = 298.7 l/hr Corrected Feed-Air Calculation at 30ºC and 34% Corrected feed-air flow: 494 l/hr x 1.25 = 617.5 l /hr