IQANsimulate 4.04 (4 Oct 2016)  [top]

Changes and new features
  23328 Download all missing simulators for multi master project
  Implemented.
Bug fixes
  27018 Incorrect simulation of impossible status on XC21
  Removed simulation of High and Low supply voltage, since these are not possible statuses for XC21.
  31893 Conflict between simulator TCP ports and other software
  Fixed.
  33483 Crash while editing simulation items
  Could happen when selecting two simulation items with different signal generators, or by deleting all rows in a signal generator of a simulation item.
Fixed.
  33549 IQANsimulate does not remember channel values
  Values for DIN and JPIN were not always remembered between simulations.
Fixed.
  33606 MD4 simulator crash at startup
  Could happen if there were channels connected to properties "External buttons" or "Backlight control" on a display page container.
Fixed.
   

IQANsimulate 4.03 (28 Jun 2016)  [top]

Changes and new features
  32461 Improved support for high resolution screens
  Improved handling of 125 % and 150% zoom in Windows.
Bug fixes
  30773 Space bar keyboard shortcut won't work until slider is selected
  Fixed.
  31717 IQANsimulate crash when sending settings
  Could happen when simulating multi-master systems.
Fixed.
   

IQANsimulate 4.02 (8 Apr 2016)  [top]

Bug fixes
  30359 IQANsimulate does not remember channel values changed via IQANdesign
  Fixed.
   

IQANsimulate 4.01.7 (16 Feb 2016)  [top]

Bug fixes
  30209 Crash when stopping simulation
  Fixed.
   

IQANsimulate 4.01.5 (11 Feb 2016)  [top]

Bug fixes
  28244 Missing texts in dropdown for DP
  Fixed.
   

IQANsimulate 4.00 (15 Dec 2015)  [top]

Changes and new features
  223 Interface to other simulation software
  ActiveX support implemented. Makes it possible to read and set values from external software, e.g. Microsoft Excel.
  2595 Add keyboard shortcut for small input changes
  In the simulation group view the arrows are used to select channel. Ctrl+arrows are used to change the value of the selected track bar. Added shift+ctrl+arrows to change values in raw value steps of 1 (smallest step available).
  4593 Signal generator
  Now possible to control the value of a simulation item using a signal generator. The signal generator contains a table with time/value pairs.
Import of measure file creates simulation items for each simulatable channel in the measure file. Values from the measure file are also imported so that you can play back a measured scenario.
  7734 Make it possible to add channels to simulation group while simulating
  Implemented.
  15217 Make it possible to "Set value" on all channels
  Implemented.
  15218 Make "Set value" function more accessible
  Added a small popup below selected channel containing controls for setting values on the channel. Same method used for physical channels and for the "set value" function for stored and adjustable channels.
  22259 Add option to be Ethernet discoverable
  Option added. Makes running simulator turn up in "Connect via Ethernet" dialog, e.g. in IQANrun.
  24171 Remember input values and settings between simulations without having to save
  Implemented.
  25307 Avoid stacking simulation items on top of each other
  Implemented.
  28059 Reset settings
  New menu item "Reset Settings" added. Will reset all adjustable and stored values to application default.